Our mission
APCS
was founded to end a 30 year monopoly of the pipe coating business
in Australia and to
provide the industry with updated coating technology and systems,
flexibility and value where the customer has traditionally received a poor
deal due to lack of competition.
Our talented, energetic
and pro-active employees provide new ideas through innovative thinking and
also focus their efforts on providing reliable, quality products combined
with a high degree of customer service. By winning new and retaining
existing customers, our corporate objectives are to gain sufficient market
share to return a profit to our principal shareholder, sustain long term
growth and provide our employees with a sense of purpose and a satisfying
work environment.
|
Top
|
Our
capabilities
Coating
-
APCS utilizes state of the art technology to apply internal
and external coatings to pipes ranging in diameter from NB50 to NB1,500 in
lengths from 9.5mtrs to 18.3mtrs*. Please refer to the
Products and Services
section for further technical information.
|
Coating process |
Type of coating |
Production capacity |
|
External systems |
2-layer Yellowkote HDPE
3-layer
Trikote® HDPE
Single layer FBE
Dual
layer FBE (for mech. protection, crossings, HDD) |
}
}>500m˛/hour
}
>250m˛/hour
|
|
Internal systems |
2 pack
epoxy flow coatings
High build epoxies |
= 20jts/hour
= Variable |
*
Investigations are underway to consider upgrades to accommodate 24mtr pipe
lengths.
|
Top
|
Pipe
storage -
The bare and coated pipe
storage area is approximately 4.5Ha in size and can accommodate the
following total quantities of pipe by size based on 18mtr
nominal lengths.
|
Pipe size |
Total storage capacity |
Stack height |
|
NB150 |
800kms
|
10
|
|
NB250 |
400kms |
8 |
|
NB350 |
280kms |
7 |
|
NB450 |
200kms |
6 |
Coated Projects
Over 100 Coating
Contracts completed in Australia -
APC
Socotherm secured and completed its' 100th coating contract in Australia
during April 2006. We would like to thank all of our customers for
their repeated continual support in helping use reach this milestone.
Our
partial reference list (does not include misc. work)
|
Month/Year |
Client |
Length (mtrs) |
Size (mm) |
Coating th’ness
(mm) |
Coating type |
Project |
|
May, 2005 |
Delco Australia Pty Ltd |
225,500
21,100 2,500
48,250 2,000
500 |
219x4.40
219x6.10 219x6.10
168x4.00 168x5.80
168x5.80 |
1.150
1.150 3.220
1.150 1.150 3.220 |
YK YK T’kote
YK YK T’kote |
Central Ranges |
|
Apr, 2005 |
Orrcon |
30,492 |
114x4.80 |
1.220 |
T’kote |
Unknown |
|
Feb, 2005 |
Orrcon |
5,000 |
324x6.40 |
0.400 |
P |
Worley Epic Kemerton Lateral |
|
Jan, 2005 |
Gasnet |
1,752 |
356x9.53 |
1,425 0.050 |
T’kote
Int |
Snowy Hydro Project
|
|
Jan, 2005 |
Technip Oceania |
10,931
390
11,041
561 |
508x15.3
508x17.7
114x4.80
114x4.80 |
0.400
1.000 1.150
1.000 |
P
P2 YK
P2 |
Woodside Otway Gas |
|
Nov, 2004 |
Santos QNTBU |
1,640
520
860
11,388
35,784 |
324x12.0
324x22.2
324x11.1
324x9.70
60.3x5.54 |
1.125
1.125 1.125
0.550 0.900 |
P2
P2 P2
P YK |
Casino Field Development |
|
Aug, 2004 |
Orrcon |
22,824 |
114x4.80 |
1.220 |
T’kote |
Unknown |
|
Feb, 2004 |
Orrcon |
25,272 |
114x4.80 |
1.275 |
T’kote |
Unknown |
|
Feb, 2004 |
Orrcon |
6,228 1,188 270 |
508x6.40 406x6.40 508x6.40 |
1.275 1.275 1.500 |
T’kote T’kote P2 |
Enertrade/CH4
|
|
Jan, 2004 |
Orrcon |
25,000 |
114x4.00 |
1.275 |
T’kote |
Unknown |
|
Dec,
2003 |
Orrcon |
18,342 1,548 |
168x4.80 168x6.40 |
1.275 1.275 |
T’kote T’kote |
Powerco/Tasmania
Laterals |
|
Oct, 2002 |
Orrcon |
2,172 7,140 1,572 3,084 7,800 |
114x4.00 114x4.80 168x7.11 114x4.00 114x4.80 |
1.150 1.150 1.150 1.150 1.150 |
YK YK YK YK YK |
Unknown |
|
Aug,2002 to May2003 |
Spie Capag/Lucas JV |
4,600 4,600 5,000 1,405 570 3,025 189,200 188,840 360 30,000 21,148 5,265 4,887 |
356x7.84 356x7.84 356x9.80 356x9.80 356x9.80 356x9.80 457x10.1 457x10.1 457x10.1 457x12.1 457x12.1 457x12.1 457x12.1 |
0.050 1.275 0.050 1.275 1.500 3.000 0.050 1.275 3.000 0.050 1.275 1.500 3.000 |
Int T’kote Int T’kote P2 T’kote Int T’kote
T’kote Int T’kote P2 T’kote |
SEAGas Australia Pty
Ltd |
|
Aug,2002 |
Orrcon |
7,284 |
114x4.80 |
1.350 |
YK |
Energex |
|
Apr,2002 |
Orrcon |
21,336 |
114x4.00 |
1.150 |
YK |
OCA/W’grove |
|
Dec,2001 |
Santos
QNTBU |
8,011 |
323x8.70 |
1.350 |
YK |
Santos/Scotia |
|
Sept,2001 |
Tubemakers Brisbane |
25,570 6,245 1,484 |
219x14.3 219x8.20 219x18.3 |
1.350 1.350 1.350 |
T’Kote T’Kote T’Kote |
Chevron/Moran Papua New Guinea |
|
June,2001 |
Agility/Tubemakers –
Brisbane |
41,153 |
406x5.70 |
1.400 |
YK |
Agility-Clough Lucas/CS Energy Roma Looping |
|
Feb,2001 |
Tubemakers –
Brisbane |
28,809 277 1,668 |
168x4.00 168x6.40 114x4.80 |
1.200 1.200 1.200 |
YK YK YK |
OCA/G’tulloch |
|
Jan, 2001 |
Tubemakers –
M’bourne |
12,277 994 |
323x4.80 323x5.70 |
1.300 1.300 |
T’Kote T’Kote |
Mission Energy/Loy Yang B |
|
Jan, 2000 |
Duke Energy Int’l |
16,825 |
219x9.10 |
1.035 |
P2 |
Duke Energy Int’l – EGP Lateral |
Legend:-
Yellowkote(YK) - 2 layer HDPE to AS1518-2002
Powderkote
(P)
- Fusion Bonded Epoxy to AS3862-2002
Powderkote II (P2)
- Dual layer FBE in general accordance with AS3862
Tri-kote®
(T’Kote)
- 3 layer HDPE (Trilaminate) to CAN/CSA-Z.245.21
Innerkote®
(Int) - Internal flow coating to API
RP5L2
Heavykote
(H)
- Concrete weight coating
(available for special projects)
|